Viking E2: the condenser fan motor on an older undercounter wine unit

On earlier Viking Professional and Designer undercounter wine units with the TruProtect control, E2 means the condenser fan motor is drawing abnormal current.

(844) 709-0727

Mon–Sat, 8am–8pm

  • Fans and airflow
  • Wine cooler fan repair
  • Source: Viking

Book a visit

Three short steps, about a minute.

or call (844) 709-0727

What E2
actually means.

On earlier Viking Professional and Designer undercounter wine units with the TruProtect control, E2 means the condenser fan motor is drawing abnormal current. Viking notes that power line fluctuations can trigger a code with nothing wrong, so it asks you to clear the code once and see whether it returns.

Viking wine cooler display

What to do when E2 shows on the wine cooler

Before you book,
in this order.

Each step comes from Viking's own guidance for E2 on its wine coolers. Follow it to the end: the last card says whether this is a visit.

01

Clear the code once, using the button sequence in the guide.

02

If E2 returns, check that the front grille is clear and listen for the fan at the bottom of the unit.

03

If E2 shows up again after clearing, book a visit.

Still there?

It usually turns into wine cooler fan repair. Book with the code and the model number.

What not to do

E2 is not a compartment temperature code. On these units E1 is listed for the compressor, and the guide’s sensor rows are not consistent, so only E2 is written up here.

What you may
notice with it.

The wine cooler problems E2 tends to arrive with. Answer these at the wine cooler before anyone is booked.

All problems

Where E2 usually leads

Wine cooler fan repair.

Circulation or condenser fan motor · low to moderate.

In Viking's own words

Condenser fan motor fault, (high/low amps).
Viking use and installation guide F20729 (earlier Professional and Designer undercounter wine units) Viking use and installation guide F20729 (earlier Professional and Designer undercounter wine units) Viking use and installation guide F20729 (earlier Professional and Designer undercounter wine units)

Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Earlier Viking undercounter wine units covered by guide F20729 (such as VUWC and DUWC models), now discontinued.

Viking E2 wine cooler repair,
where we come out.

The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.

All service areas
A couple choosing a bottle together from an undercounter wine cooler in a warm kitchen at dusk
For the heart of your home.

Questions
about E2.

Can I clear E2 myself?
Clear the code once, using the button sequence in the guide. If it comes back, it needs a visit.
Can a power surge cause E2 on an old Viking wine unit?
Viking says power line fluctuations can show a code with nothing wrong, which is why you clear it once first.
What does the condenser fan do?
It pulls air across the condenser to carry away heat. Without it, the unit runs hot and struggles to cool.
Are parts still available for discontinued Viking wine units?
Many condenser fan motors are standard parts, but some model-specific parts may not be. The visit confirms what can be sourced.