The inside rear wall of an empty wine cooler with the racks pulled out, a small temperature probe clipped to the wall and its thin lead running into a grommet.

Perlick P1F: a wine zone probe has stopped reading

P1F and P2F are the G5 probe alarms for zone 1 and zone 2.

(844) 709-0727

Mon–Sat, 8am–8pm

  • Temperature sensors
  • Wine cooler thermostat and sensor repair
  • Source: Perlick

Book a visit

Three short steps, about a minute.

or call (844) 709-0727

What P1F
actually means.

P1F and P2F are the G5 probe alarms for zone 1 and zone 2. Perlick asks you to acknowledge the code; if it repeats within a week, service is needed. With a zone probe out, the control cannot hold that zone properly.

Perlick wine cooler display · also shown as P2F

What to do when P1F shows on the wine cooler

Before you book,
in this order.

Each step comes from Perlick's own guidance for P1F on its wine coolers. Follow it to the end: the last card says whether this is a visit.

01

Acknowledge the alarm on the display.

02

Check the zone with a thermometer over the next day.

03

If P1F or P2F returns within a week, book a visit.

Still there?

It usually turns into wine cooler thermostat and sensor repair. Book with the code and the model number.

What not to do

P1F is not a high or low temperature alarm; the zone may still be fine for now. The evaporator probe has its own code, PEF.

What you may
notice with it.

The wine cooler problems P1F tends to arrive with. Answer these at the wine cooler before anyone is booked.

All problems

Where P1F usually leads

Wine cooler thermostat and sensor repair.

Thermostat or zone temperature sensor · low to moderate.

In Perlick's own words

P1F Zone 1 Probe Fault
Perlick G5 User Installation & Operation Manual, Form Z3023 (linked from the G5 Luxe 24-inch wine reserve page) Perlick G5 User Installation & Operation Manual, Form Z3023 (linked from the G5 Luxe 24-inch wine reserve page) Perlick G5 User Installation & Operation Manual, Form Z3023 (linked from the G5 Luxe 24-inch wine reserve page)

Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Perlick G5 Core and G5 Luxe wine reserves with the touch display, single-zone (URS15W, URS24W) and dual-zone (URS24D). Up to ten past alarms stay listed, with date and time stamps, under Alarm History.

Perlick P1F wine cooler repair,
where we come out.

The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.

All service areas
A couple choosing a bottle together from an undercounter wine cooler in a warm kitchen at dusk
For the heart of your home.

Questions
about P1F.

Can I clear P1F myself?
Acknowledge the alarm on the display. If it comes back, it needs a visit.
What does acknowledging P1F do?
It clears the active alarm. If the probe really has failed, it returns within a week, which is Perlick’s signal that service is needed.
Is P2F possible on a single-zone Perlick?
Perlick uses zone 2 only on dual-zone units, so P2F belongs to dual-zone reserves.
Can the zone still cool with P1F?
It may, but not accurately. Keep a thermometer in that zone until the probe is replaced.

Back to your everyday

Still showing P1F?

When you book, copy the code or the blink pattern as the display shows it, add the whole model number, and say whether the bottles still feel cool — a code gives the technician a head start.